Restored from previous forum. Originally posted by Hitman.
There's a HiResTimer library in the PB drawer, but I can't find the related documents or command reference, do anyone knows how to use it......
Thanks very much.
Well, everyone needs to do something for living.
"Timer" Commands?
-
BackupUser
- PureBasic Guru

- Posts: 16777133
- Joined: Tue Apr 22, 2003 7:42 pm
Restored from previous forum. Originally posted by Danilo.
The HighResTimer library is in "UserLibraries",
so its not supported by Frederic.
I will release it with official HelpFile later,
but this should help you:
Example 1:
Example 2:
cya,
...Danilo
(registered PureBasic user)
Edited by - Danilo on 01 July 2002 01:01:15
The HighResTimer library is in "UserLibraries",
so its not supported by Frederic.
I will release it with official HelpFile later,
but this should help you:
Code: Select all
[b]StartTimer( #Timer, MilliSec, @proc() )[/b]
#Timer = Timer-Number (0-15)
MilliSec = Milliseconds
@proc() = your Procedure
Starts a Timer. The procedure @proc() is called
every MilliSec.
The Timer-Procedure cant have any Parameters
and runs in its own thread (so make needed
variables SHARED in the procedure).
[b]EndTimer( #Timer )[/b]
#Timer = Timer-Number (0-15)
Ends the Timer.
[b]x = GetMinTimerResolution()[/b]
Get the minimal timer resolution.
The minimal Timer resolution is different
on Win9x and WinNT/2k.
On NT based Systems (NT/2k, dunno about XP)
it should be 1 millisecond. On Win9x based
system this value can be different.
[b]x = GetMaxTimerResolution()[/b]
Get the maximal Timer Resolution.
The max resolution is different on misc.
Windows systems.
Values up to 1 Minute (60.000ms) should be
OK on all systems.
Example 1:
Code: Select all
;--------------------
;--------------------
Procedure mytimer1()
Shared hoehe
If hoehe = 1000: hoehe = 100: EndIf
beep_(hoehe,100)
hoehe+100
EndProcedure
Procedure mytimer2()
beep_(1800,5)
EndProcedure
Procedure mytimer3()
beep_(1800,100)
EndProcedure
Procedure mytimer4()
beep_(800,100)
EndProcedure
hWnd = OpenWindow(0, (GetSystemMetrics_(#SM_CXSCREEN)-200)/2,(GetSystemMetrics_(#SM_CYSCREEN)-277)/2, 400, 360, #PB_Window_SystemMenu|#PB_Window_SizeGadget, "High Resolution Timer by Danilo")
StartTimer(0, 1000, @mytimer1())
StartTimer(1, 200, @mytimer2())
StartTimer(2, 2000, @mytimer3())
StartTimer(3, 600, @mytimer4())
Repeat
Select WaitWindowEvent()
; IF LeftMouseButton pressed...
Case #WM_LBUTTONDOWN
EndTimer(1): EndTimer(2): EndTimer(3)
; pressed CloseButton or ALT+F4 ??
Case #PB_EventCloseWindow
End
EndSelect
ForEver
;--------------------
;--------------------Example 2:
Code: Select all
;--------------------
;--------------------
Global myText$
Global hWnd.l
Global TextLength.l
#ScrollSpeed_in_Milliseconds = 70
myText$ = " This is a little Scroller-Test with the Timer by Danilo "
TextLength = Len(myText$)
Procedure Scroller()
;Shared Scroller_a
Shared Scroller_Position
Shared Scroller_Direction
If Scroller_Position > 1
Procedure Timer()
Shared y, size, flag, color
y+#ScreenHeight/200 : If y > #ScreenHeight : y=0 : EndIf
color = (size<<3)-1
If size < 32 And flag = 0
size+1
Else
flag = 1 : size-1 : If size = 0 : flag = 0 : EndIf
EndIf
EndProcedure
;DirectX init
If InitSprite() = 0 Or InitKeyboard() = 0
MessageRequester("ERROR","Can't initialize DirectX 7 or later", 0):End
EndIf
If OpenScreen(#ScreenWidth,#ScreenHeight,#ScreenBits,"Timer Test") = 0
MessageRequester("ERROR","Can´t open DirectX screen",0):End
EndIf
; Start the Timer-Procedure
StartTimer(0,15,@Timer())
; Wait for Escape-Key
Repeat
ExamineKeyboard()
FlipBuffers()
If IsScreenActive()
ClearScreen(0,0,0)
StartDrawing(ScreenOutput())
FrontColor(color,color,0)
Box(x-size/2,y,size,size)
StopDrawing()
Else
Delay(200)
EndIf
Until KeyboardPushed(#PB_Key_Escape)
; End Program
EndTimer(0)
Delay(20)
End
;--------------------
;--------------------cya,
...Danilo
(registered PureBasic user)
Edited by - Danilo on 01 July 2002 01:01:15
-
BackupUser
- PureBasic Guru

- Posts: 16777133
- Joined: Tue Apr 22, 2003 7:42 pm
-
BackupUser
- PureBasic Guru

- Posts: 16777133
- Joined: Tue Apr 22, 2003 7:42 pm
Restored from previous forum. Originally posted by ebs.
Danilo,
One question please: What happens if I call StartTimer() on a timer that's already started? I would be calling StartTimer() with identical parameters - the same timer number, milliseconds, and procedure. Will this cause any problems? I know that it doesn't make a lot of sense to do this, but otherwise I have to put in additional logic to determine when to end and restart the timer.
Thanks,
Eric
Danilo,
One question please: What happens if I call StartTimer() on a timer that's already started? I would be calling StartTimer() with identical parameters - the same timer number, milliseconds, and procedure. Will this cause any problems? I know that it doesn't make a lot of sense to do this, but otherwise I have to put in additional logic to determine when to end and restart the timer.
Thanks,
Eric
The HighResTimer library is in "UserLibraries",
so its not supported by Frederic.
I will release it with official HelpFile later,
but this should help you:
cya,
...Danilo
(registered PureBasic user)
Edited by - Danilo on 01 July 2002 01:01:15
-
BackupUser
- PureBasic Guru

- Posts: 16777133
- Joined: Tue Apr 22, 2003 7:42 pm
Restored from previous forum. Originally posted by Danilo.
If you call with the same timer-number again,
the old timer is closed and the new timer initialized.
So you can use the same Timer number again and again -
the old timer is closed automatically.
cya,
...Danilo
(registered PureBasic user)
If you call with the same timer-number again,
the old timer is closed and the new timer initialized.
Code: Select all
StartTimer( 1, 1000, @mytest() ) ; start a timer with speed 1000ms
StartTimer( 1, 500, @mytest() ) ; now the same timer (virtual) with more speed
StartTimer( 1, 500, @cool() ) ; still 500ms, but another timer-procedure
the old timer is closed automatically.
cya,
...Danilo
(registered PureBasic user)
-
BackupUser
- PureBasic Guru

- Posts: 16777133
- Joined: Tue Apr 22, 2003 7:42 pm
Restored from previous forum. Originally posted by ebs.
Danilo,
Perfect! Thanks for your quick reply.
Eric
Danilo,
Perfect! Thanks for your quick reply.
Eric
If you call with the same timer-number again,
the old timer is closed and the new timer initialized.
So you can use the same Timer number again and again -Code: Select all
StartTimer( 1, 1000, @mytest() ) ; start a timer with speed 1000ms StartTimer( 1, 500, @mytest() ) ; now the same timer (virtual) with more speed StartTimer( 1, 500, @cool() ) ; still 500ms, but another timer-procedure
the old timer is closed automatically.
cya,
...Danilo